Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
International Journal of Stem Cells ; : 202-211, 2020.
Article | WPRIM | ID: wpr-834290

ABSTRACT

Background and Objectives@#p21, an important member of the Cip/Kip family, is involved in inhibitory effects of RUNX1b overexpression during the early stage of human hematopoiesis. @*Methods@#and Results: We established a human embryonic stem cell (hESC) line with inducible expression of p21 (p21/hESCs). Overexpression of p21 did not influence either mesoderm induction or emergence of CD34+ cells, but it significantly decreased the production of CD43+ cells and changed the expression profile of hematopoiesis-related factors, leading to the negative effects of p21 on hematopoiesis. @*Conclusions@#In RUNX1b/hESC co-cultures when RUNX1b was induced from D0, perturbation of the cell cycle caused by upregulation of p21 probably prevented the appearance of CD43+ cells, but not CD34+ cells. The mechanisms via which CD34+ cells are blocked by RUNX1b overexpression remain to be elucidated.

2.
Environmental Health and Preventive Medicine ; : 55-55, 2019.
Article in English | WPRIM | ID: wpr-777586

ABSTRACT

OBJECTIVES@#We assessed the role of social support in presenteeism by examining organizational commitment among Chinese healthcare workers.@*METHODS@#One thousand four hundred thirty-four healthcare workers from 6 hospitals in 4 Chinese cities completed a questionnaire measuring presenteeism, social support, and organizational commitment. With organizational commitment as the mediator, regression analyses and structural equation modeling were used to test the model.@*RESULTS@#Organizational commitment was directly inversely associated with presenteeism (β = - 0.42, p 0.05). The correlation between supervisor support and coworker support was significant (β = 0.71, p <0.001). Supervisor support and coworker support were significantly positively associated with organizational commitment (β = 0.41, p < 0.001, and β = 0.14, p < 0.001, respectively).@*CONCLUSIONS@#Supervisor support was more important in promoting organizational commitment, while coworker support was more effective in reducing presenteeism. The mediating effect of organizational commitment was significant.

3.
Clinical Medicine of China ; (12): 262-264, 2017.
Article in Chinese | WPRIM | ID: wpr-513186

ABSTRACT

Objective To analyze the clinical application value of endometrial collector combined with liquid based cytology and histological examination for screening of endometrial cancer.Methods One hundred and eighty-two cases high-risk people with endometrial cancer in Songgang People's Hospital of Bao'an district of Shenzhen from June 2014 to December 2015 were collected,among them 71 patients with endometrial cancer were found in the patients who were diagnosed by pathological diagnosis,and the remaining 111 were not diagnosed with endometrial cancer.The material satisfaction,sample collection time of sample collection and endometrial curettage device were comparatively analyzed and also the cervical dilatation production rate,the amount of bleeding,pain score(VAS) were analyzed.The application value of endometrial collector combined with liquid based cytology and histological examination for screening of endometrial cancer was judged according to the results obtained.Results There was no significant difference between the two methods based on satisfaction(χ2=1.953,P=0.089).A methods of cervical endometrial expansion rate(3.85% vs.93.96%) and acquisition time((16.35±2.19) min vs.(11.23±4.26) min),bleeding volume((1.64±0.63) ml vs.(15.73±5.41) ml),VAS score((0.82±0.24) points vs.(4.34±2.43) points) were significantly lower than that of curettage sample collection method(χ2=16.473,P=0.000;t=5.733,P=0.034;t=11.183,P=0.000;t=3.618,P=0.043).With curettage pathological diagnosis as the gold standard,the specificity,sensitivity and diagnostic coincidence rate of endometrial biopsy combined with liquid based cytology and histological examination for screening endometrial carcinoma were respectively 94.51%,95.05% and 94.96%.Conclusion Compared with curettage sampling method,endometrial curettage collector has features of high success rate,short time,low pain and high security and the cervical dilation rate is low.Endometrial curettage collector can be combined with liquid based cytology and histology to examine and screen endometrial cancer.This methods is worth promoting.

4.
Chinese Journal of Ultrasonography ; (12): 291-293, 2015.
Article in Chinese | WPRIM | ID: wpr-463518

ABSTRACT

Objective To propose an accurate method of noninvasive determination of central venous pressure(CVP ) by locating the central point of right atrium (RA ) using echocardiography .Methods Through the 3D reconstruction ,the accurate positions of RA of 30 patients who had been examined by multislice 3‐dimensional computed tomography for chest imaging were recorded .Based on solid geometric principles ,the central point in RA was located by echocardiography and then compared with CT‐location point .The accuracy and feasibility were assessed by absolute distance (Da) ,vertical distance (Dv) and the whole time of location (T) between the two points .Results Mean Da ,Dv and T of the whole subjects were 07.6cm(95% CI:06.2to08.1cm),01.6cm(95% CI:-00.2to03.4cm),and438.0s(95% CI:400.1to 47 4.0 s) ,respectively .Conclusions The echocardiographic method on the basis of solid geometry proposed in this study could be used to locate the central point in RA accurately and simply .Thus it would be helpful to improve the accuracy of noninvasive determination of central venous pressure .

5.
Chinese Journal of Ultrasonography ; (12): 196-198, 2015.
Article in Chinese | WPRIM | ID: wpr-466127

ABSTRACT

Objective To determine the central venous pressure (CVP) noninvasively based on hemodynamics principles using ultrasound location of the collapse point of the internal jugular vein.Methods Forty patients were enrolled in this study.The collapse point of the internal jugular vein was located and marked by a linear transducer,the body mark of right atrium was marked on the right lateral wall of the chest.The noninvasive CVP was calculated according to the vertical distance between those two points.The invasive CVP determination by central venous catheter was also carried out on all the patients.Correlation analysis was used to compare the invasive and noninvasive methods.With invasive determination of CVP as the gold standard,the ROC curve of the noninvasive ultrasound method was sketched to explore the optimal cut-off points.Results The correlation analysis reveal high positive correlation between CVPs determined by ultrasound imaging and central venous catheter (r =0.906,P <0.01).By the ROC curve test,fluid column height of 10.75 cm by ultrasound method was determined as the cut-off point,with the sensitivity and specificity of diagnosing elevation of CVP being 88.9% and 93.5 % respectively.The corresponding area under the curve was 0.971.Conclusions Ultrasound imaging could be used to determine CVP noninvasively,which would be helpful in diagnosis of the circulating load of patients.

6.
Chinese Journal of Ultrasonography ; (12): 1067-1069, 2013.
Article in Chinese | WPRIM | ID: wpr-439220

ABSTRACT

Objective To investigate the affecting factors of interventricular septum (IVS) swing by study of the mechanical model of the respiration-driven variation of cardiac function using echocardiography.Methods In present study,the equivalent mechanical model of septal swing in previous study was used.By changing the end-diastolic pressure difference between the simulated right and left ventricles and simulated intrapericardial pressure,the subsequent influences on IVS swing using echocardiography were observed.Results Under the rhythmic respiratory intrathoracic pressure change(RIPC)(0--4 mm Hg,1 mm Hg =0.133 kPa),the swing amplitude of simulated IVS increased with decrease of the simulated end-diastolic pressure difference between the simulated right and left ventricles (2.2-17.6 mm).With increasing of the simulated intrapericardial pressure,the simulated right ventricle and left ventricle collapsed in succession,the swing amplitude of simulated IVS also increased to a maximal amplitude of 22.4 mm.Conclusions The affecting factors of IVS swing including the magnitude of RIPC,the end-diastolic pressure difference between the two ventricles and the intrapericardial pressure.

SELECTION OF CITATIONS
SEARCH DETAIL